            Always reliable switching and controlling

            Switching and Control

            Semiconductor contactors have proven themselves in industrial applications everywhere high switching frequencies or high switching cycles are required. With their long service lives and wear-free switching, they handle switching and controlling tasks in specific applications in a highly economical manner.

             

            Safety technology is becoming more and more important in machine and equipment construction. Safety modules or even safety controllers are being used everywhere. Despite the increasing use of semiconductors, electromechanical relays remain an important component of such systems. The have the task of switching loads and galvanically separating electrical circuits. Classical applications, particularly for relays with mechanical force-guided contacts, are in the monitoring of emergency stop switches, safety doors or light barriers, for example. They are also essential in railway signalling equipment as well as in the controllers for passenger and goods elevators as well as in medical equipment. Our PCB relays are available in a great variety of different contact variants and construction forms and guarantee the highest switching safety with minimal dimensions.

            Solid state contactor BF 9250

            • According to IEC/EN 60 947-4-2, IEC/EN 60 947-4-3
            • 1-, 2- and 3-pole models
            • Load current up to 50 A
            • For AC load up to 480 V
            • Switching at zero crossing
            • Protected by varistors
            • As option temperature protection of the power semiconductors
            with monitoring output
            • Mounting on DIN-rail
            • As option with...

            Solid-state relay / contactor for resistive load PK 9260

            • AC solid-state relay / -contactor
            • PK 9260/_ _ _ according to IEC/EN 62314
            PK 9260/_ _ _ / _ _ according to IEC/EN 60947-4-2 and -4-3
            • Load current up to 88 A, AC-51
            • Switching at zero crossing for resistive loads
            • 2 anti-parallel thyristors
            • DCB technology (direct bonding method) for excellent
            heat transmission...

            Solid-state contactor with current monitoring BH 9251

            • According to IEC/EN 60 947-1, IEC/EN 60 947-4-2
            • Switching at zero crossing
            • To switch single-phase AC load up to 400 V
            • Compensates voltage fluctuations of ± 20 %
            • Load current up to 40 A
            • Monitors:
            - Undercurrent
            - Overcurrent
            - Interrupted load circuit
            - monitors temperature to protect the power semiconductor
            •...

            Solid-state relay / contactor PH 9260

            • AC semiconductor relay / -contactor
            • According to IEC/EN 60947-4-3
            • Load current up to 125 A, AC 51 with I2t up to 18000 A2s
            • Switching at zero crossing
            • As option switching at voltage maximum
            • 2 anti-parallel thyristors
            • DCB technology (direct bonding method) for excellent
            heat transmission properties
            •...

            Solid-state relay / contactor with load circuit monitoring PH 9270

            • AC solid-state relay /-contactor
            • With integrated load circuit monitoring
            • Settable load limit value
            • According to IEC/EN 60947-4-3
            • Load current 40 A, AC 51
            • Switching at zero crossing
            • 2 anti-parallel thyristors
            • DCB technology (direct bonding method) for excellent
            heat transmission properties
            •...

            Safety relays OA 5623

            • According to DIN EN 61810-1, DIN EN 61810-3
            • With forcibly guided contacts
            • Clearance and creepage distances:
            contact - contact ≥ 5,5 mm
            • Low rated power consumption and holding power
            • High mechancial service life
            • High temperature range
            • High thermal continuous current
            • Height: 15.8 mm

            Bistable relay OB 5623

            • According to DIN EN 61810-1, DIN EN 61810-3
            • With forcibly guided contacts
            • Energy efficient; Low energy consumption, because of impulse control,
            no holding consumption
            • Bistable
            Mechanical latching of contact position
            • Safe separation between all current circuits
            • Both coils non-polarised, neutral
            • Defined...

            Safety relays OA 5642

            • According to DIN EN 61810-1, DIN EN 61810-3,
            DIN EN 45545 (fire protection on railway vehicles)
            • With forcibly guided contacts
            • Safe separation betwenn coil/contact and contact/contact for
            applications at pollution degree 2 with rated insulation voltage 250 V
            • Clearance and creepage distances
            contact - coil ≥ 5.5 mm
            contact -...

            Safety relays OA 5643

            • According to DIN EN 61810-1, DIN EN 61810-3,
            DIN EN 45545 (fire protection on railway vehicles)
            • With forcibly guided contacts
            • Safe separation betwenn coil/contact and contact/contact for
            applications at pollution degree 2 with rated insulation voltage 250 V
            • Clearance and creepage distances
            contact - coil ≥ 5.5 mm
            contact -...

            Safety relays OA 5644

            • According to DIN EN 61810-1, DIN EN 61810-3,
            DIN EN 45545 (fire protection on railway vehicles)
            • With forcibly guided contacts
            • Safe separation betwenn coil/contact and contact/contact for
            applications at pollution degree 2 with rated insulation voltage 250 V
            • Clearance and creepage distances
            contact - coil ≥ 5.5 mm