            Solutions for the food and beverage industry

            Food and beverage industry

            The degree of automation in the food and beverage industry is also continuously increasing due to ever stricter hygiene requirements and growing cost pressure. Alongside the hygiene compatibility of the technologies used, energy efficiency also plays an important role. A number of continuously recurring process steps, such as baking, heating, drying and so on are highly energy-intensive. Optimization of the electrical equipment also generates savings.

            Residual current monitor, Type B RN 5883

            • According to IEC/EN 62 020, VDE 0663
            • For AC and DC systems Type B
            • To detect earth faults in grounded voltage systems
            • 4 setting ranges from 10 mA to 3 A
            • Manual reset, with alarm and pre-warning
            • With adjustable switching delay
            • Energized or de-energized on trip
            • LED indicator for operation, pre-alarm and...

            Solid-state relay / contactor for resistive load PK 9260

            • AC solid-state relay / -contactor
            • PK 9260/_ _ _ according to IEC/EN 62314
            PK 9260/_ _ _ / _ _ according to IEC/EN 60947-4-2 and -4-3
            • Load current up to 88 A, AC-51
            • Switching at zero crossing for resistive loads
            • 2 anti-parallel thyristors
            • DCB technology (direct bonding method) for excellent
            heat transmission...

            Solid-state relay / contactor PH 9260

            • AC semiconductor relay / -contactor
            • According to IEC/EN 60947-4-3
            • Load current up to 125 A, AC 51 with I2t up to 18000 A2s
            • Switching at zero crossing
            • As option switching at voltage maximum
            • 2 anti-parallel thyristors
            • DCB technology (direct bonding method) for excellent
            heat transmission properties
            •...

            Solid-state relay / contactor, 2-poles PH 9260.92

            • AC solid-state relay / -contactor
            • According to IEC/EN 60947-4-3
            • As option load current up to 2 x 32 A or 2 x 48 A
            • As option with hight I²t up to 6600 A²s
            • Load voltages up to AC 480 V
            • 2 anti-parallel thyristors for each pole
            • DCB technology (direct bonding method) for excellent
            heat transmission...

            Softstarter with DC-brake BI 9028

            • According to IEC/EN 60947-4-2
            • 2-phase motor control
            • For motors up to 15 kW at 3 AC 400 V
            • Separate settings for start and brake time, as well as starting
            and braking torque
            • Galvanic isolation of control input
            with wide voltage range up to AC/DC 230 V
            • No external motor or braking contactor necessary
            • 3...