            Solutions for renewable energy

            Renewable energy

            Whether they provide photovoltaic, wind or water power, the number of power generation plants using renewable energy continues to grow. The operators of these plants attach great importance to efficiency and economy. Only by means of proper system solutions for the control and monitoring of power generation can competitive efficiency be achieved. Only a high level of efficiency can create the economic basis for replacing electricity from fossil fuels. In addition, it is important that safety-related issues are considered.

            Locating current injector RR 5886

            • Insulation troubleshooting in AC, DC and AC/DC networks (IT systems)
            in connection with the insulation fault locator RR 5887 according to
            DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1 (VDE 0413-1)
            • Insulation coordination according to IEC 60664-1
            • External control via insulation monitor possible
            • Positive and negative test...

            Insulation fault locator RR 5887

            • Insulation troubleshooting in AC, DC and AC/DC networks (IT systems)
            in connection with the locating current injector RR 5886 according to
            DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1 (VDE 0413-1)
            • Insulation coordination according to IEC 60664-1
            • Connection of max. 4 or 8 measuring current transformers depending
            on the design
            •...

            Smart motorstarter UG 9256

            • According to IEC/EN 60 947-4-2
            • To reverse 3 phase motors from 90 W to 750 W resp. 550 W to 4 kW
            at AC 400 V
            • 2-phase softstart
            • Max. 4 potentiometer für setting of starting torque, deceleration torque,
            softstart /-stop, overcurrent limit or rated motor current
            • 4 LEDs for status indication
            • Reversing with relays...

            Insulation monitor RN 5897/010

            • Insulation monitoring according to IEC/EN 61557-8
            • Trigger output for insulation fault locating system
            • 2 separate adjustable response thresholds
            (using e.g. for pre-Alarm and Alarm)
            • Setting range of 1st response value (Pre-Alarm): 20 kΩ … 2 MΩ
            • Setting range of 2nd response value (Alarm): 1 kΩ...

            Insulation monitor RN 5897/300

            • Insulation monitoring according to IEC/EN 61557-8
            • 2 separate adjustable response thresholds
            (using e.g. for pre-Alarm and Alarm)
            • Setting range of 1st response value (Pre-Alarm): 20 kΩ … 1 MΩ:
            • Setting range of 2nd response value (Alarm): 10 kΩ … 250 kΩ
            • 2 changeover contacts für...

            Latching relay MK 8852

            • According to IEC/EN 61 810-1
            • Setting input A1 - A2
            • Reset input A3 - A2
            • Storage function
            • Switch position indication
            • Manual operation
            • Width 22.5 mm

            Insulation monitor LK 5894

            • Insulation monitoring according to IEC/EN 61557-8
            • Detection of symmetric and asymmetric insulation faults
            • 2 changeover contacts
            • Prewarning threshold setting range: 20 kΩ ... 2 MΩ
            • Alarm threshold setting range: 1 kΩ ... 250 kΩ
            • Energized or de-energized on trip can be selected for output...

            Insulation monitor LK 5895

            • Insulation monitoring according to IEC/EN 61557-8
            • Detection of symmetric and asymmetric insulation faults
            • Measuring circuits can be disconnected via control terminals, e.g. for mains couplings
            • 1 changeover contact each for prewarning and alarm
            • Prewarning threshold setting range: 20 kΩ ... 2 MΩ
            • Alarm...

            Latching relay AD 8851

            • According to IEC/EN 61 810-1
            • Manual operation possible
            • Contact position indication via control lever
            • max. 4 NC contacts, 4 NO contacts
            • Width 45 mm

            Insulation monitor LK 5896

            • Insulation monitoring according to IEC/EN 61557-8
            • Detection of symmetric and asymmetric insulation faults
            • Measuring circuits can be disconnected via control terminals, e.g. for mains couplings
            • 1 changeover contact each for prewarning and alarm
            • 3. output relay for signalling wire break and device faults
            •...