            Safety relays with forcibly guided contacts

            Safety relays with forcibly guided contacts

            Energy efficiency and safety for your applications

            In the machine- and plantbuilding sector the safety becomes more and more important. Everywhere, safety modules and also safety control systems are used. Despite the increasing use of semiconductor relays, the electromechanical relays are still an important part. Safety relays, i.e. relays with mechanically forcibly guided contacts per DIN EN 61810-3, are used wherever people, machines and valuable goods must be protected from injury and damage. One such relay comprises at least one NC contact set and one NO contact set and is constructed such that the NC set and the NO set can never be closed at the same time. For example, if a NO contact fails when trying to open, the associated NC contact cannot close when the power supply is switched off.

            Please select required language:

            Documentation, Application and processing instructions PCB relays, File: pdf, File size 273 KB

            Flyer, Safety relays OA 5642/43/44, File: pdf, File size 236 KB

            Flyer, Safety relay OA 5621/22/23, File: pdf, File size 267 KB

            Flyer, Bistable relay OB 5623, File: pdf, File size 210 KB

            Brochure, Catalog PCB relays, File: pdf, File size 4 MB

            Brochure, Image brochure PCB relays, File: pdf, File size 1 MB

            Choose a product:

            Type of relay

            Contact equipping

            Contact material

            Continuous current

            Test voltage (AC) contact set - coil

            Clearance and creepage distances, contact set - coil ≥

            Type according to DIN EN 61810-3

            Protection type

            Approvals

            For relay type

            Safety relays OA 5669

            • According to DIN EN 61810-1, DIN EN 61810-3 (Type A resp. Type B)
            • With forcibly guided contacts
            • Clearance and creepage distances
            contact-coil ≥ 8 mm,
            contact - contact ≥ 5.5 mm
            Double and reinforced insulation between contact sets
            • Low rated power consumption
            • High mechanical service life
            • Compact size, small...

            Safety relays OA 5669/3___

            • According to DIN EN 61810-1, DIN EN 61810-3
            • With forcibly guided contacts
            • Clearance and creepage distances:
            contact - coil ≥ 8 mm,
            contact - contact ≥ 5.5 mm
            double and reinforced insulation between contact sets
            • Low rated power consumption
            • High mechanical service life
            • For high ambient temperature up to +...

            Safety relays OA 5667

            • According to DIN EN 61810-1, DIN EN 61810-3
            • With forcibly guided contacts
            • Clearance and creepage distances:
            contact-coil ≥ 8 mm
            version OA 5667.16 with double and reinforced insulation
            • Low rated power consumption
            • High mechanical service life
            • Compact size, small height

            Safety relays, reinforc. insulation OA 5667/_____4

            • According to DIN EN 61810-1, DIN EN 61810-3
            • With forcibly guided contacts
            • Clearance and creepage distances:
            contact - coil ≥ 8 mm
            contact - contact ≥ 5,5 mm
            Double and reinforced insulation between contacts
            • Low rated power consumption
            • High voltage resistance ≥ 4 kV at contamination level 2
            • High mechanical...

            Safety relays OA 5670

            • According to DIN EN 61810-1, DIN EN 61810-3
            • With forcibly guided contacts
            • double and reinforced insulation between contact sets
            acc. to EN 50178
            • High dielectric strength
            • High mechanical service life
            • High switching reliability
            • Compact size
            • High thermal continuous current
            • High voltage range
            •...

            Safety relays OA 5611

            • According to DIN EN 61810-1, DIN EN 61810-3
            • With forcibly guided contacts
            • High switching reliability due to crown contacts
            • Low rated power consumption
            • High mechanical service life
            • High temperature range - 40 ... + 85°C
            • High continiuous thermal current Ith = 8 A
            • Compact size
            • Optionally wash...

            Safety relays, sensitiv OA 5611/____S

            • According to DIN EN 61810-1, DIN EN 61810-3
            • With forcibly guided contacts
            • High switching reliability due to crown contacts
            • Very low rated power consumption
            OA 5611: 0.36 W with 4 contacts
            OA 5612: 0.5 W with 6 contacts
            • High mechanical service life
            • High temperature range - 40 ... + 85°C
            • Compact size

            Safety relays, according DIN EN 50578 OA 5611/31__L1

            • Acc. to DIN EN 61810-1, DIN EN 61810-3, DIN EN 50578 (UIC 736)
            • With forcibly guided contacts
            • High switching reliability due to crown contacts
            • Low rated power consumption
            • High mechanical service life
            • High continiuous thermal current Ith = 8 A
            • Compact size

            Safety relays OA 5612

            • According to DIN EN 61810-1, DIN EN 61810-3
            • With forcibly guided contacts
            • High switching reliability due to crown contacts
            • Low rated power consumption
            • High mechanical service life
            • High temperature range - 40 ... + 85°C
            • High continiuous thermal current Ith = 8 A
            • Compact size
            • Optionally wash...

            Safety relays, sensitiv OA 5612/____S

            • According to DIN EN 61810-1, DIN EN 61810-3
            • With forcibly guided contacts
            • High switching reliability due to crown contacts
            • Very low rated power consumption
            OA 5611: 0.36 W with 4 contacts
            OA 5612: 0.5 W with 6 contacts
            • High mechanical service life
            • High temperature range - 40 ... + 85°C
            • Compact size

            Safety relays OA 5621

            • According to DIN EN 61810-1, DIN EN 61810-3
            • With forcibly guided contacts
            • Clearance and creepage distances:
            contact - contact ≥ 5,5 mm
            • Low rated power consumption and holding power
            • High mechancial service life
            • High temperature range
            • High thermal continuous current
            • 15,5 mm height
            • Version with...

            Safety relays with double contacts OA 5621_D

            • According to DIN EN 61810-1, DIN EN 61810-3
            • With forcibly guided contacts
            • High switching safety because of gold plated double contacts
            • Clearance and creepage distances:
            contact - contact ≥ 5,5 mm
            • Low rated power consumption and holding power
            • High mechancial service life
            • High temperature range
            • High...

            Safety relays OA 5622

            • According to DIN EN 61810-1, DIN EN 61810-3
            • With forcibly guided contacts
            • Clearance and creepage distances:
            contact - contact ≥ 5,5 mm
            • Low rated power consumption and holding power
            • High mechancial service life
            • High temperature range
            • High thermal continuous current
            • 15,5 mm height
            • Version with...

            Safety relays with double contacts OA 5622_D

            • According to DIN EN 61810-1, DIN EN 61810-3
            • With forcibly guided contacts
            • High switching safety because of gold plated double contacts
            • Clearance and creepage distances:
            contact - contact ≥ 5,5 mm
            • Low rated power consumption and holding power
            • High mechancial service life
            • High temperature range
            • High...

            Safety relays OA 5623

            • According to DIN EN 61810-1, DIN EN 61810-3
            • With forcibly guided contacts
            • Clearance and creepage distances:
            contact - contact ≥ 5,5 mm
            • Low rated power consumption and holding power
            • High mechancial service life
            • High temperature range
            • High thermal continuous current
            • Height: 15.8 mm

            Bistable relay OB 5623

            • According to DIN EN 61810-1, DIN EN 61810-3
            • With forcibly guided contacts
            • Energy efficient; Low energy consumption, because of impulse control,
            no holding consumption
            • Bistable
            Mechanical latching of contact position
            • Safe separation between all current circuits
            • Both coils non-polarised, neutral
            • Defined...

            Safety relays OA 5601

            • According to DIN EN 61810-1, DIN EN 61810-3
            • With forcibly guided contacts
            • High switching reliability due to crown contacts
            • Clearance and creepage distances:
            contact - coil ≥ 8 mm
            contact - contact ≥ 5.5 mm
            Double and reinforced insulation with pollution degree 2
            Overvoltage category: III
            • High voltage resistance ≥...

            Safety relays OA 5602

            • According to DIN EN 61810-1, DIN EN 61810-3
            • With forcibly guided contacts
            • High switching reliability due to crown contacts
            • Clearance and creepage distances:
            contact - coil ≥ 8 mm
            contact - contact ≥ 5.5 mm
            Double and reinforced insulation with pollution degree 2
            Overvoltage category: III
            • High voltage resistance ≥...

            Safety relays OA 5603

            • According to DIN EN 61810-1, DIN EN 61810-3
            • With forcibly guided contacts
            • High switching reliability due to crown contacts
            • Clearance and creepage distances:
            contact - coil ≥ 8 mm
            contact - contact ≥ 5.5 mm
            Double and reinforced insulation with pollution degree 2
            Overvoltage category: III
            • High voltage resistance ≥...

            Safety relays, according DIN EN 50578 OA 5603/39__L1

            • Acc. to DIN EN 61810-1, DIN EN 61810-3, DIN EN 50578 (UIC 736)
            • With forcibly guided contacts
            • High switching reliability due to crown contacts
            • Clearance and creepage distances:
            contact - coil ≥ 8 mm
            contact - contact ≥ 5.5 mm
            Double and reinforced insulation with pollution degree 2
            Overvoltage category: III
            • High...

            Safety relays OA 5642

            • According to DIN EN 61810-1, DIN EN 61810-3,
            DIN EN 45545 (fire protection on railway vehicles)
            • With forcibly guided contacts
            • Safe separation betwenn coil/contact and contact/contact for
            applications at pollution degree 2 with rated insulation voltage 250 V
            • Clearance and creepage distances
            contact - coil ≥ 5.5 mm
            contact -...

            Safety relays OA 5643

            • According to DIN EN 61810-1, DIN EN 61810-3,
            DIN EN 45545 (fire protection on railway vehicles)
            • With forcibly guided contacts
            • Safe separation betwenn coil/contact and contact/contact for
            applications at pollution degree 2 with rated insulation voltage 250 V
            • Clearance and creepage distances
            contact - coil ≥ 5.5 mm
            contact -...

            Safety relays OA 5644

            • According to DIN EN 61810-1, DIN EN 61810-3,
            DIN EN 45545 (fire protection on railway vehicles)
            • With forcibly guided contacts
            • Safe separation betwenn coil/contact and contact/contact for
            applications at pollution degree 2 with rated insulation voltage 250 V
            • Clearance and creepage distances
            contact - coil ≥ 5.5 mm
            contact -...